Fire cabinets are one of the most important tools for small-scale fires that are in the growth phase and are still capable of being extinguished by manual intervention. The ergonomic structure of the pulley and the rubber properties of the hoses make it suitable for both amateur and educated personnel. There are fire cabinets designed for the use of amateur personnel in the building, as well as variants designed for trained personnel. All installation and procurement procedures of the fire cabinets, which are the most important means of providing manual intervention to the fire, are presented to the customers by GCS Engineering Fire Safety Systems
Doors are doors with a fire-resistance rating and play an important role in fire protection and loss prevention. They are used as part of a passive fire protection system to reduce the spread of fire or smoke between compartments. Fire Doors enable safe escape from a building or structure during events like fire, earthquake, etc. Since Fire Doors have a distinct purpose, they have additional special characteristics than those of ordinary doors.
We offer an ample range of fire-rated doors including Steel Doors, Glazed Doors, Access Panel Doors, Louvers, Vision Panels & Associated hardware accessories
Projecting, design, consulting, application, supervision, and contracted maintenance operations All components of the sprinkler systems made by experienced personnel of GCS Engineering Fire Safety Systems are imported from America and Europe and all system elements have international reputations such as FM, UL, VdS, LPCB. GCS Engineering Inc. is being designed by experienced engineering staff, and also by GCS Engineering. The field is assembled by the team, subject to international standards. All system designs are based on NFPA13 and TS EN 12845 standards, while NFPA25 (NFPA Test and Maintenance, Inspection) standards are taken into account for the maintenance phase. Accuracy of incorrect application and installation has vital importance for the effective operation of automatic sprinkler systems. For the systems to operate by the standards and to be effective in extinguishing any possible fire, the sprinkler systems are installed by the “NFPA 13: Standard for the Installation of Sprinkler Systems” standards. The maintenance phases, which also have vital provisions for the effective operation of the systems for many years, are also in line with the “NFPA 25: Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems” standards
Micro quenching systems – the most effective system for protecting electrical panels, machine cabinets, machine control units, and other small cabinets – all of the cabinet quenching systems are manufactured by GCS Engineering. imported from abroad by GCS Engineering. The suppression gas, which is under the pressure of 11 bar across the cylinder and tubing, is discharged from the place where the tubing or sensing element senses the heat and extinguishes the fire at the point where it is full. It can be used to protect more than one panel or it can be designed for single panel protection. Due to the use of suppression agents in small quantities and the direct effect of the source of fire, quenching systems for microchannels are now highly preferred suppression systems. The cylinder sizes used in the panel – micro suppression systems can be 1, 2, 4, or 6 liters. Tubing size can be used in the intervals allowed by standard and manufacturer manuals. All gas and materials used in the system are of first-class quality, with FM, UL, GOST, or VdS approvals.
Fires, which often occur due to work accidents or negligence, are among the disasters that cause loss of life and property. Fires do not qualify as natural disasters because they are largely preventable. With simple measures to be taken, it is possible to prevent fires from breaking out and to control them in a short time after they are released. Fire safety systems are of great importance at this point. Thanks to the fire safety systems, which have many types according to their areas of use, the damages of fires are largely prevented. Co2 fire suppression systems are also among these security systems. Oxygen plays an important role in the initiation and growth of fires. The more flammable materials and flames come into contact with oxygen, the faster it burns. – Carbon dioxide fire suppression system reduces the oxygen in the environment thanks to the carbon dioxide it releases into the environment and provides rapid cooling. Depending on the need, systems can be installed at different pressure values. Before installation, it is necessary to determine the requirements well and to install the installation with the appropriate tubes
Fires that break out in homes and workplaces due to various accidents or negligence cause both financial losses and losses of lives. Responding as soon as possible after the fire starts ensures that these losses are minimized. Automatic fire extinguishing systems are the best option at this point. These systems which are connected to an alarm sensor and command center are activated by increasing temperature and respond to fire from many points at the same time. Automatic fire extinguishing systems also have different types depending on their areas of use and purpose. The foam sprinkler system is also part of this variety. Foam sprinkler systems are preferred in areas where fire extinguishing with water is not sufficient. The foam sprinkler system, which is usually found in facilities, aircraft hangars, and fuel stations where flammable liquids and chemicals are used, breaks the air contact with fire by forming a dense layer and ensures that the fire is extinguished in a shorter time
Detection and denunciation systems are of great importance for minimizing risk in times of danger. For example, early detection of a fire that has not yet grown in an environment will give the earliest opportunity to put the fire to the relevant personnel or automatic extinguishing system, and the loss of life and property will be eliminated. Likewise, early detection of any explosive gas accumulated in an environment will allow early intervention (such as ventilation) to act and release the gas from the environment. This will eliminate the possibility of an explosive atmosphere and possible fire. Fire detection and notification systems are set up to detect fires that occur as a general principle at the earliest possible time and to send them to the relevant places using signals. Gas detection systems open the way to the early intervention by transmitting the presence of a gas, which is even higher than the level normally allowed in the environment, to the relevant panels
Being informed early on in the event of a fire will enable early intervention possibilities as well as prevent loss of life and property. Therefore, these systems have maximum protection in terms of fire safety. All fire detection and notification systems supplied by GCS Engineering from abroad and capable of producing any necessary solutions are products with EN 54, VdS, FM, UL, ULC, or LPCB approvals. Relevant to fire detection systems • Addressable fire detection and notification systems • Conventional fire detection and notification systems as well as systems that belong to or are part of these systems. • Fire Panel Graphics Software • Air sampling fire detection systems • Line-type linear fire detection systems • Spark detectors – spark detectors • Channel-type detectors • Flame detectors
©2023. GCS. All Rights Reserved.